Operating Temperature and Cable Length for Testing in Thermal Chamber
Operating Temperature it can support up to 70deg (by design) but the unit is only tested at 25 deg ambient. The unit is not intended to work for the automotive...
Operating Temperature it can support up to 70deg (by design) but the unit is only tested at 25 deg ambient. The unit is not intended to work for the automotive...
Currently we do not support, but it is a part of our future roadmap.
Yes, our hardware is compatible with 1.0 and 1.1 specifications.
We have fixed 2.2 kΩ pull-ups on the PGY-I3C-EX-PD. The values for the pull-ups are fixed and cannot be changed. That said, users do have the provision to either enable...
We currently do not have the provision to generate a tLOW of 24ns in push-pull mode at 12.5MHz as the duty cycle parameter has a resolution of only 10ns. Hence,...
tC0 has a resolution of fine 18ps. Hence, the closest value that can be specified to 37.5 is either 37.504 or 37.486.
To exit the I3C mode and switch the bus back to the I2C mode, simply issue a ‘RSTDAA’ command in the script, which clears the dynamic address assignment. This action...
Please find example scripts for sending the HDR Write and READ commands below. HDR_WRITE: Script: SysOD tLOW:2000 tHIGH:40 tCAS:2000 Script: SysFreq:1000 tHIGH:50 tLOW:50 tCO:10 Script: SysExtended tSU_STA:20 tSU_STO:20 { Script:Bus...
Please find example scripts to generate this scenario below Example: Script: SysOD tLOW:2000 tHIGH:40 tCAS:2000 Script: SysFreq: 500tHIGH:50tLOW:50tCO:10 Script: SysExtended tSU_STA:20 tSU_STO:50 Script:Bus Frame: Private Address:7E Transfer: WRITE Data:NA
Prodigy Response: The user can set the Trans Count to zero by setting the ‘Trans Count’ keyword to 0 as given in the script below. //////////////////////////////////////////////////////////////////////////////////////////// Script: SysOD tLOW:2000 tHIGH:40...